Trade Select Sarking HD PC:TSHD Dimensions 1500mm x 60 m (90 m2), & 1500mm x 30 m (45 m2), Thickness: 0.12mm & it comes in 1350mm too

0 out of 5

Benefits

Trade Select® Sarking is a Heavy-Duty radiant barrier, designed for multi-purpose use as both roof sarking and a wall wrap. The reflective foil side provides Thermal Control and extra R-value when installed facing an air cavity. The multi-layer structure provides superior strength, flexibility, and durability. Classified as a Water Barrier and Class 2 Vapour Barrier, Trade Select® Sarking acts as a barrier to air, radiant heat, moisture ingress and dust penetration.

  • The all-round weather barrier
  • Superior strength, puncture resistant
  • Water and Air Barrier, Class 2 Vapour Barrier
  • Low Flammability, suitable for all BALs in bushfire-prone areas
  • Group 1 Fire performance classification for wall/ceiling lining

Downloads

Datasheet Trade Select Sarking HD

Description

Material Properties and Classifications

Trade Select® Sarking classifications in accordance with AS/NZS 4200.1:2017.

 

Criteria Reference Result Requirement
Resistance to Dry Delamination AS/NZS 4201.1:1994 Pass Pass
Resistance to Wet Delamination AS/NZS 4201.2:1994 Pass Pass
Shrinkage (Repeated wetting & drying) AS/NZS 4201.3:1994 0.0% < 0.5%
Nominal Thickness 0.12 mm Value
Electrical Conductivity AS/NZS 4200.1:2017 Conductive Classification
Duty AS/NZS 4200.1:2017 Heavy Classification
Tensile Strength Machine Direction AS 1301.448s-2019 13.9 kN/m Min 12.5 kN/m
Tensile Strength Lateral Direction AS 1301.448s-2019 9.0 kN/m Min 7.5 kN/m
Edge Tear Machine Direction TAPPI T 470 om-89 586 N Min 80 N
Edge Tear Lateral Direction TAPPI T 470 om-89 367 N Min 80 N
Air Control AS/NZS 4200.1:2017 Air Barrier Classification
Emittance Value AS/NZS 4200.1:2017 Printed side: 0.90, Foil side: 0.03 Value
Emittance Classification AS/NZS 4200.1:2017 IR Non-reflective, IR Reflective Classification
Emittance Category AS/NZS 4200.1:2017 RN Category
Vapour Control AS/NZS 4200.1 Clause 5.3.2.3 Class 2 Vapour Barrier Class 1 to 4
Vapour Permeance ASTM E96-2016 Procedure B 0.004 µg/N.s Value
Water Control AS/NZS 4201.4:1994 Water Barrier Classification
Flammability Index AS/NZS 4200.1:2017 Low ≤ 5 High (> 5) / Low (≤ 5)