Trade Select FireSark PC:TSFS Dimensions 1350mm x 30m (40.5 m2) Thickness: 0.20mm

0 out of 5

Benefits

  • Trade Select® FireSark® is an Extra Heavy Duty radiant barrier, designed for multipurpose use in all roof and wall types where fire performance is a priority.  The reflective foil side provides extra R-Value when installed facing an air cavity, and the non-combustible glass fabric multi-layer structure provides excellent fire and ember resistance, as well as superior strength, flexibility and durability.Classified as a Water Barrier, and Class 2 Vapour Barrier. Trade Select® FireSark® is abarrier to embers, radiant heat, moisture ingress, draughts and dust penetration.> Ember-proof

    >   Ideal for all BAL zones to FZ  bushfire-prone areas

    Water and Air Barrier

    > Class 2 Vapour Barrier

    > 97% Reflective

Description

Material Properties and Classifications

Trade Select® FireSark® classifications in accordance with AS/NZS 4200.1:2017

Criteria Reference Result Requirement
Combustibility AS 1530.1-1994 Not deemed combustible Fibreglass weave
Resistance to Dry Delamination AS/NZS 4201.1:1994 Pass Pass
Resistance to Wet Delamination AS/NZS 4201.2:1994 Pass Pass
Moisture Shrinkage AS/NZS 4201.3:1994 0.0% < 0.5%
Nominal Thickness 0.20 mm ≤ 1mm
Electrical Conductivity AS/NZS 4200.1:2017 Conductive Classification
Duty AS/NZS 4200.1:2017 Extra Heavy Classification
Tensile Strength Machine Direction AS 1301.448s-91 58 kN/m Min 13.0 kN/m
Tensile Strength Lateral Direction AS 1301.448s-91 26 kN/m Min 10.5 kN/m
Edge Tear Machine Direction TAPPI T 470 om-89 381 N Min 90 N
Edge Tear Lateral Direction TAPPI T 470 om-89 440 N Min 90 N
Air Control ISO 6536/5-2003 Air Barrier Classification
Emittance Value AS/NZS 4201.5:1994 Printed  side: 0.90, Foil side: 0.03 Value
Emittance Classification AS/NZS 4200.1:2017 IR Non-reflective, IR Reflective Classification
Emittance Category AS/NZS 4200.1:2017 RN Category
Vapour Control ASTM E96 Class 2 Vapour Barrier Class 1 to 4
Vapour Permeance ASTM E96 0.003 µg/N.s Value
Water Control AS/NZS 4201.4:1994 Water Barrier Classification
Flammability Index AS 1530.2-1993 Low ≤ 5 High (> 5) / Low (≤ 5)
Early Fire Hazard Indices AS/NZS 1530.3-1999 0, 0, 0, 2 0 – 20, 0, 0 – 10, ≤ 3